iio: cros_ec: Use default frequencies when EC returns invalid information
authorGwendal Grignou <gwendal@chromium.org>
Tue, 30 Jun 2020 15:37:30 +0000 (08:37 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 24 Nov 2020 12:39:10 +0000 (13:39 +0100)
commit3fc7b9b8055fb50752ff9ed55b85aafd6086a32f
tree12173554db4b52b7896f876b19816a7c3669457f
parentfb9488a9bd0bdf728db98d04f470e86d2fa20f5c
iio: cros_ec: Use default frequencies when EC returns invalid information

commit 56e4f2dda23c6d39d327944faa89efaa4eb290d1 upstream.

Minimal and maximal frequencies supported by a sensor is queried.
On some older machines, these frequencies are not returned properly and
the EC returns 0 instead.
When returned maximal frequency is 0, ignore the information and use
default frequencies instead.

Fixes: ae7b02ad2f32 ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs")
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Link: https://lore.kernel.org/r/20200630153730.3302889-1-gwendal@chromium.org
CC: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/common/cros_ec_sensors/cros_ec_sensors_core.c