net: ks8851: Set initial carrier state to down
authorLukas Wunner <lukas@wunner.de>
Wed, 20 Mar 2019 14:02:00 +0000 (15:02 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 16 May 2019 07:17:15 +0000 (09:17 +0200)
commit90a9d6d23c0eef54f1eed9d403d7e6d2aea9832d
treee65de5be27f8c24fbd0c5c6ee45c130ac4d1f376
parentcd30c290a14d1c824ace33f0cc432b2a4615be86
net: ks8851: Set initial carrier state to down

[ Upstream commit 9624bafa5f6418b9ca5b3f66d1f6a6a2e8bf6d4c ]

The ks8851 chip's initial carrier state is down. A Link Change Interrupt
is signaled once interrupts are enabled if the carrier is up.

The ks8851 driver has it backwards by assuming that the initial carrier
state is up. The state is therefore misrepresented if the interface is
opened with no cable attached. Fix it.

The Link Change interrupt is sometimes not signaled unless the P1MBSR
register (which contains the Link Status bit) is read on ->ndo_open().
This might be a hardware erratum. Read the register by calling
mii_check_link(), which has the desirable side effect of setting the
carrier state to down if the cable was detached while the interface was
closed.

Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: Frank Pavlic <f.pavlic@kunbus.de>
Cc: Ben Dooks <ben.dooks@codethink.co.uk>
Cc: Tristram Ha <Tristram.Ha@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin (Microsoft) <sashal@kernel.org>
drivers/net/ethernet/micrel/ks8851.c