net: ks8851: Set initial carrier state to down
authorLukas Wunner <lukas@wunner.de>
Wed, 20 Mar 2019 14:02:00 +0000 (15:02 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 4 May 2019 07:15:20 +0000 (09:15 +0200)
commitb6ca8ec8bb742625e8b2e19e1fcbb3936a543cef
tree3da768bbbac2c11834b0a61d1e42b3b2cac9fe37
parent64e8347986d0962dfbb335c5a6754bb261c69aa9
net: ks8851: Set initial carrier state to down

[ Upstream commit 9624bafa5f6418b9ca5b3f66d1f6a6a2e8bf6d4c ]

The ks8851 chip's initial carrier state is down. A Link Change Interrupt
is signaled once interrupts are enabled if the carrier is up.

The ks8851 driver has it backwards by assuming that the initial carrier
state is up. The state is therefore misrepresented if the interface is
opened with no cable attached. Fix it.

The Link Change interrupt is sometimes not signaled unless the P1MBSR
register (which contains the Link Status bit) is read on ->ndo_open().
This might be a hardware erratum. Read the register by calling
mii_check_link(), which has the desirable side effect of setting the
carrier state to down if the cable was detached while the interface was
closed.

Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: Frank Pavlic <f.pavlic@kunbus.de>
Cc: Ben Dooks <ben.dooks@codethink.co.uk>
Cc: Tristram Ha <Tristram.Ha@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin (Microsoft) <sashal@kernel.org>
drivers/net/ethernet/micrel/ks8851.c