staging: comedi: das6402: Fix endian problem for AI command data
authorIan Abbott <abbotti@mev.co.uk>
Tue, 23 Feb 2021 14:30:45 +0000 (14:30 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 17 Mar 2021 15:43:50 +0000 (16:43 +0100)
commitd079c097128d3d1bd0c6925a2be3207547d013aa
tree22f05e0940295820a40f63e878d948bfe5f0fcee
parente83788603af8d1d274c8b8e797bdc8b510929f6a
staging: comedi: das6402: Fix endian problem for AI command data

commit 1c0f20b78781b9ca50dc3ecfd396d0db5b141890 upstream.

The analog input subdevice supports Comedi asynchronous commands that
use Comedi's 16-bit sample format.  However, the call to
`comedi_buf_write_samples()` is passing the address of a 32-bit integer
variable.  On bigendian machines, this will copy 2 bytes from the wrong
end of the 32-bit value.  Fix it by changing the type of the variable
holding the sample value to `unsigned short`.

Fixes: d1d24cb65ee3 ("staging: comedi: das6402: read analog input samples in interrupt handler")
Cc: <stable@vger.kernel.org> # 3.19+
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Link: https://lore.kernel.org/r/20210223143055.257402-5-abbotti@mev.co.uk
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/das6402.c